    Using the Dymo S50 USB Scale Driver
    • 09 Jul 2024
    • 2 Minutes to read
    • Contributors

    Using the Dymo S50 USB Scale Driver


    Article summary

    A guide to the Dymo S50 Scale driver and Tulip.

    This article describes the capabilities and configuration associated with the Dymo S50 Scale driver in Tulip.

    Dymo Scale1.jpeg

    Capabilities

    This driver is meant to receive data from Dymo USB scales (M10 and S50) through an Edge Device or a Windows Tulip Player, in the format:

    {
    unitOfMeasure: 'string',
    measurement: 'float',
    stable: 'boolean',
    overloaded: 'boolean',
    }

    Driver Location: Edge Devices, Windows Tulip Player

    Supported Devices

    • Dymo M10 VID: 2338, PID: 32771
    • Dymo S50 VID: 2338, PID: 32777

    Driver Configuration

    To configure the driver for the Dymo S50 Scale, follow these steps:

    1. Navigate to the Edge Devices configuration page (located in the Shop Floor tab) or via the urls: http://[edgeDevicesIP]/driverConfig or http://[10.0.3.1]/driverConfig

    Dymo Scale2.png

    1. Assign the Edge Device to a Station, and enable the "DYMO-USB-SCALE" driver in the station configuration by selecting Configure Drivers.

    Dymo Scale3.png

    1. In the Windows Tulip Player, go to the Station and select the station that the driver is connected to. Select Interface (display device), then Configure Devices.
    2. Enable the “DYMO-USB-SCALE” driver.

    Dymo Scale4.png

    Scale Output

    • Unit of measure - g/oz/kg/lb - based on what the scale is set.
    • Measurement - the raw measurement that the scale outputs
    • Stable - yes/no - after 4 exact measurements the scale is deemed stable
    • Overloaded - yes/ no - If there is more weight on the scale than the upper limit, the scale reports that it is overloaded

    Dymo Scale5.png

    Scale Error

    The scale outputs an error when it is overloaded.

    Dymo Scale6.png

    The scale also outputs an error when the driver loses connection to the device or if connectivity issues occur between the driver and the device.

    Dymo Scale7.png

    App Configuration

    To use the driver in an app, route a trigger to match the following logic:

    Dymo Scale9.png